In order to pass HP certification HP0-S17 exam, selecting the appropriate training tools is very necessary. And professional study materials about HP certification HP0-S17 exam is a very important part. Our ITCertKing can have a good and quick provide of professional study materials about HP certification HP0-S17 exam. Our ITCertKing IT experts are very experienced and their study materials are very close to the actual exam questions, almost the same. ITCertKing is a convenient website specifically for people who want to take the certification exams, which can effectively help the candidates to pass the exam.
ITCertKing not only provide the products which have high quality to each candidate, but also provides a comprehensive after-sales service. If you are using our products, we will let you enjoy one year of free updates. So that you can get the latest exam information in time. We will be use the greatest efficiency to service each candidate.
ITCertKing HP HP0-S17 exam information are cheap and fine. We use simulation questions and answers dedication to our candidates with ultra-low price and high quality . We sincerely hope that you can pass the exam. We provide you with a convenient online service to resolve any questions about HP HP0-S17 exam questions for you.
About HP0-S17 exam, ITCertKing has a great sound quality, will be the most trusted sources. Feedback from the thousands of registration department, a large number of in-depth analysis, we are in a position to determine which supplier will provide you with the latest and the best HP0-S17 practice questions. The ITCertKing HP HP0-S17 training materials are constantly being updated and modified, has the highest HP HP0-S17 training experience. If you want to pass the exam,please using our ITCertKing HP HP0-S17 exam training materials. ITCertKing HP HP0-S17 Add to your shopping cart, it will let you see unexpected results.
Exam Code: HP0-S17
Exam Name: HP (Integrating and Managing HP BladeSystem in the Enterprise)
One year free update, No help, Full refund!
Total Q&A: 130 Questions and Answers
Last Update: 2014-01-26
Those who want to prepare for the IT certification exam are helpless. But they have to do it. So they have restless state of mind. However, With ITCertKing HP HP0-S17 exam training materials, the kind of mentality will disappear. With ITCertKing's HP HP0-S17 exam training materials, you can be brimming with confidence, and do not need to worry the exam. Of course, you can also face the exam with ease. This is not only psychological help, but more importantly, it allows you to pass the exam and to help you get a better tomorrow.
In order to protect the vital interests of each IT certification exams candidate, ITCertKing provides high-quality HP HP0-S17 exam training materials. This exam material is specially developed according to the needs of the candidates. It is researched by the IT experts of ITCertKing. Their struggle is not just to help you pass the exam, but also in order to let you have a better tomorrow.
HP HP0-S17 certification exam is very important for every IT person. With this certification you will not be eliminated, and you will be a raise. Some people say that to pass the HP HP0-S17 exam certification is tantamount to success. Yes, this is true. You get what you want is one of the manifestations of success. ITCertKing of HP HP0-S17 exam materials is the source of your success. With this training materials, you will speed up the pace of success, and you will be more confident.
HP0-S17 Free Demo Download: http://www.itcertking.com/HP0-S17_exam.html
NO.1 A customer has a Virtual Connect managed enclosure and needs to move one of the blades to a
non-virtual connect enclosure.
What should be done so that duplicate MAC addresses and WWNs do not appear in the datacenter due
to server blade deployment?
A.Enable the Reset to factory default switch on the blade system board.
B.Run the erase utility on the blade before plugging the server to the network.
C.First delete all MAC and WWNs configurations while the server is in the VC managed enclosure and
then move the server to the non-VC managed enclosure.
D.MAC addresses and WWNs are automatically returned to factory defaults when the server is moved to
the non-Virtual connect enclosure so no duplicate MAC addresses or WWNs appear.
ANSWER: D
HP HP0-S17 braindump HP0-S17 dumps HP0-S17 exam prep
NO.2 Which interconnect option creates domains and stacks LAN modules across c7000 Enclosures?
A.GbE2c Ethernet
B.Virtual Connect Ethernet
C.Ethernet Pass-Thru Module
D.Virtual Connect Fibre Channel
ANSWER: B
HP test questions HP0-S17 original questions HP0-S17 HP0-S17 dumps HP0-S17 pdf
NO.3 Which features does Virtual Connect Ethernet module (VC-Enet) provide in a network environment?
(Select two.)
A.VC-Enet can stack across four enclosures in a rack.
B.VC-Enet appears as an HP ProCurve device to other network devices.
C.VC-Enet will not add any new switches for the network administrator to manage.
D.VC-Enet domains can be created directly using the Onboard Administrator console.
ANSWER: AC
HP HP0-S17 exam HP0-S17
NO.4 A customer is looking for a virtualization solution for their data center. Their main area of concern is
server down time.
You have identified the x86-based virtualization candidates. Which platform best suits the customer's
needs?
A.scale-up
B.scale-out
C.Integrity VSE
D.single server virtual consolidation
ANSWER: B
HP HP0-S17 HP0-S17 certification training HP0-S17 pdf
NO.5 An administrator configures an HP c7000 Enclosure using Onboard Administrator. Which option can
be used to automatically configure IP addresses for all iLO cards and interconnect modules?
A.Insight Display
B.Virtual Connect Manager
C.Interconnect LAN Manager
D.Enclosure Bay IP Addressing (EBIPA)
ANSWER: D
HP HP0-S17 HP0-S17 HP0-S17
NO.6 Which devices can be assigned an IP address through Enclosure Bay IP Addressing (EBIPA) for
c-Class server blades? (Select two.)
A.iLO 2 cards
B.interconnects
C.Insight Display
D.LAN interfaces of mezzanine cards
E.iSCSI target IP address on server blades
ANSWER: AB
HP HP0-S17 pdf HP0-S17 HP0-S17
NO.7 An administrator needs to monitor performance of every drive connected to the Smart Array controller.
Each drive is configured as a single logical drive.
Which tool can be used?
A.Insight Diagnostic
B.Radia Performance Manager
C.Performance Management Pack
D.Windows Server Performance Monitor
ANSWER: C
HP original questions HP0-S17 HP0-S17 certification HP0-S17 test HP0-S17 pdf HP0-S17 test
NO.8 Which interconnect module offered by HP has the capability of assigning a configuration profile to a
specific server blade?
A.GbE2c Switch
B.Cisco 3020 Switch
C.Virtual Connect Ethernet
D.Ethernet Pass-Thru Module
ANSWER: C
HP HP0-S17 HP0-S17 original questions HP0-S17
NO.9 What is an advantage of a c7000 Enclosure compared to a c3000 Enclosure in an enterprise
environment?
A.N+N redundancy in the power subsystem
B.Virtual Connect and storage blade support
C.interconnect redundancy for integrated NICs
D.application of Onboard Administrator advanced license
ANSWER: C
HP certification HP0-S17 HP0-S17
NO.10 Your customer wants to replace an existing c3000 Enclosure with a c7000 Enclosure. Which
components from the c3000 Enclosure can be reused in the c7000 Enclosure? (Select three.)
A.fans
B.power supplies
C.interconnect modules
D.server and storage blades
E.Onboard Administrator module
ANSWER: ACD
HP HP0-S17 HP0-S17 HP0-S17 practice test HP0-S17
NO.11 What is the purpose of the HP StorageWorks SB40c Storage Blade?
A.provides a blade form factor tape solution for any server supporting the TCP/IP protocol
B.provides a blade form factor networked shared storage for any server supporting IP-based storage
(iSCSI)
C.provides additional storage capabilities dedicated to a single server blade within the same c7000
Enclosure
D.provides additional storage capabilities dedicated to a single server blade in another linked c7000
Enclosure
ANSWER: C
HP HP0-S17 HP0-S17 practice test HP0-S17 HP0-S17
NO.12 Which industry standard processor options are supported in the HP BL460c Server Blade? (Select two.)
A.Dual-Core Intel Xeon
B.Quad-Core Intel Xeon
C.Dual-Core Intel Itanium2
D.Dual-Core AMD Opteron
E.Quad-Core AMD Opteron
ANSWER: AB
HP HP0-S17 HP0-S17 exam dumps HP0-S17 answers real questions
NO.13 After replacing a failed drive in a server blade, your customer complains about long logical drive time
recovery. What can you do to reduce recovery time?
A.Migrate the logical drive to RAID 6.
B.Install MPIO software on the server blade.
C.Set the rebuild priority to high on the controller.
D.Enable the Tagged Command Queuing (TCQ) feature on the hard drive.
ANSWER: C
HP answers real questions HP0-S17 questions HP0-S17 HP0-S17 certification training
NO.14 A customer that usually works with a c3000 Enclosure needs to use the external DVD drive on a
c7000 Enclosure and connect the drive to all servers in the c7000 Enclosure.
How can the external DVD drive on the c7000 Enclosure be accessed?
A.Use the DVD drive integrated in the c7000 Enclosure.
B.Use the DVD drive connected to the downlink port of the c7000 Enclosure.
C.Use the DVD drive connected to the USB port on an Onboard Administrator module.
D.Use the DVD drive attached through the serial/USB/video cable attached to any server blade.
ANSWER: C
HP braindump HP0-S17 test questions HP0-S17 answers real questions HP0-S17 test questions
NO.15 A BladeSystem enclosure is managed by one Onboard Administrator that failed. Which functionality is
still available? (Select two.)
A.iLO 2 is accessible.
B.All fans are up and running.
C.Server blades can access the SAN.
D.New server blades can be added and powered up.
E.New interconnect devices can be added and powered up.
ANSWER: BC
HP demo HP0-S17 exam simulations HP0-S17 certification HP0-S17 HP0-S17 HP0-S17 study guide
NO.16 Which industry standard technologies are compatible with the SB600c AiO Storage Blade? (Select
two.)
A.ATA
B.SAS
C.SCSI
D.iSCSI
E.SATA
ANSWER: BD
HP dumps HP0-S17 HP0-S17 exam
NO.17 Which management suite delivers core management functionality for the HP BladeSystem solution,
including server deployment, health monitoring, performance monitoring, vulnerability scanning and patch
management?
A.HP Storage Essentials
B.HP Operations Software
C.Insight Control Environment
D.HP Systems Insight Manager
ANSWER: C
HP HP0-S17 demo HP0-S17
NO.18 Your customer has a c7000 Enclosure and two power supplies installed in bays 1 and 2. They are
switching from single-phase power to a three-phase power subsystem with full redundancy.
Which action is necessary to make this configuration work and be supported?
A.Install 4 additional power supplies.
B.Move the power supplies to bays 1 and 4.
C.Turn off the Dynamic Power Saver feature.
D.Enable three-phase power using the Onboard Administrator.
ANSWER: A
HP HP0-S17 questions HP0-S17
NO.19 Which industry standard protocols are used by HP SIM? (Select two.)
A.XML
B.TFTP
C.iSCSI
D.WBEM
E.NetBEUI
ANSWER: AD
HP HP0-S17 test answers HP0-S17
NO.20 The Virtual Connect Fibre Channel module uses which type of Port ID Virtualization protocol to
aggregate multiple Fibre Channel HBAs over a smaller number of physical uplinks?
A.E_Port
B.F_Port
C.L_Port
D.N_Port
ANSWER: D
HP practice test HP0-S17 test answers HP0-S17 practice test
NO.21 Which tool tests and evaluates the hardware and software configuration of systems where HP SIM is
installed or is being considered for installation?
A.Insight Control Advisor
B.HP SIM Capacity Planner
C.Active Answers Solution Sizer
D.Site Installation Preparation Utility
ANSWER: A
HP pdf HP0-S17 test HP0-S17 practice test HP0-S17 exam HP0-S17 study guide
NO.22 You are administrating several c-Class enclosures and are looking for a unified authentication system
for all iLO cards and Onboard Administrator modules.
What is the proper solution?
A.HP Protect Tools
B.Credential Manager
C.Virtual Connect Enterprise Manager
D.Lightweight Directory Access Protocol (LDAP)
ANSWER: D
HP HP0-S17 certification training HP0-S17 HP0-S17 HP0-S17 braindump HP0-S17
NO.23 Which service features are included in the Enhanced Network Installation and Startup Service for
BladeSystem Switches? (Select two.)
A.service planning interview
B.network device configuration
C.comprehensive porting and migration
D.systematic analysis of configurations for software patch version inconsistencies
E.proactive and rapid-response services to protect strategic operations against downtime risks
ANSWER: AB
HP HP0-S17 demo HP0-S17
NO.24 A customer wants to deploy a c7000 Enclosure and six server blades in a datacenter with limited
power. How can they ensure the solution fits within the available datacenter power envelope?
A.The customer needs to make sure they have at least 6750 watts of available power in every case.
B.Use the HP BladeSystem Sizer to determine how much power is needed for the configuration they want
to deploy.
C.Use the HP Rack and Power tool to determine how much power is needed for the configuration they
want to deploy.
D.Use the Enterprise Configurator in ActiveAnswers to determine how much power is needed for the
configuration they want to deploy.
ANSWER: B
HP pdf HP0-S17 dumps HP0-S17
NO.25 Which ProLiant Essentials Value Pack is an integrated power monitoring and management
application that provides centralized monitoring and control of datacenter power consumption and thermal
output?
A.Insight Power Manager
B.HP Rack and Power Manager
C.Performance Management Pack
D.Vulnerability and Patch Management Pack
ANSWER: A
HP HP0-S17 HP0-S17 study guide
NO.26 Your customer is looking for an Ethernet interconnect with Fibre uplinks for their c7000 Enclosure.
Which interconnects should be considered? (Select two.)
A.GbE2c Switch
B.Infiniband switch
C.Cisco Catalyst 3020
D.GbE2c Layer 2/3 Switch
E.Ethernet Pass-Thru Module
ANSWER: CD
HP pdf HP0-S17 HP0-S17 HP0-S17
NO.27 Which industry standard memory technologies are supported in a BL465c Server Blade? (Select two.)
A.memory sparing
B.memory mirroring
C.memory interleaving
D.ECC and Advanced ECC
E.833MHz maximum speed DIMMs
ANSWER: CD
HP HP0-S17 HP0-S17 HP0-S17
NO.28 Which service features are included in the Enhanced Network Installation and Startup Service for
BladeSystem Switches? (Select two.)
A.verification of operation
B.confirmation of software revisions
C.comprehensive porting and migration
D.systematic analysis of configurations for software patch version inconsistencies
E.proactive and rapid-response services to protect strategic operations against downtime risks
ANSWER: AB
HP HP0-S17 demo HP0-S17 demo
NO.29 You are replacing one of your redundant GbE2c interconnect switch modules in your c7000 Enclosure.
What must you be aware of when you install a replacement GbE2C switch with default settings into the
enclosure?
A.Crosslink ports are disabled and redundancy is lost between switches.
B.Crosslink ports are enabled and will cause a loop in your switch topology.
C.Uplink ports are disabled and must be enabled manually in the switch manager.
D.Downlink ports are disabled and must be enabled manually in the switch manager.
ANSWER: A
HP HP0-S17 HP0-S17 HP0-S17 demo HP0-S17
NO.30 Which industry standard memory technology can be used by Intel Xeon-based c-Class server blades
to provide additional protection against failed or degrading FB-DIMMs? (Select two.)
A.Advanced ECC
B.mirrored memory
C.registered DIMMs
D.online spare memory
E.interleaved memory support
ANSWER: BD
HP exam prep HP0-S17 HP0-S17 demo HP0-S17
ITCertKing offer the latest 1Z1-536 exam material and high-quality HP2-E56 pdf questions & answers. Our 700-501 VCE testing engine and 000-283 study guide can help you pass the real exam. High-quality HP2-N43 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertking.com/HP0-S17_exam.html
没有评论:
发表评论